Yokogawa’s TDLSTM8200 is a dual laser gas analyzer that measures the concentration of O2, CO, CH4, NH3, HCl ,which are important for combustion control and safety related measurements with the ability to measure various other NIR absorbing gases.
The TDLS8200 is installed in-situ, directly into the process eliminating the need for sample extraction and conditioning providing a near real time measurement. The single flange design reduces installation costs and expands installation flexibility where traditional cross-duct analyzers were not feasible due to obstructions or accessibility. Based on solid-state technology means virtually no measurement drift and reduced calibration frequency. The analyzer auto-gain feature and reference cell ensures measurements are unaffected by dynamic process conditions, upsets, or varying background composition to maintain real time measurements.
The modular design of the TDLS8200 allows for full field serviceability with the ability to replace components without having to return the analyzer to the manufacturer. A storage period of up to 50 days of data, spectra, and history files (validation and configuration changes) allow for advanced diagnostics and provides invaluable information into analyzer performance and process details.
Features
• Dual laser measurement technology allows for O2, CO, and CH4 to be measured in-situ with a single analyzer
• TruePeakTM combined with smart laser technology
- Measurement integrates the area of the absorbance and gets a true, interference-free analysis under changing pressure, temperature, and background.
- Laser Detector Module is replaceable on site without any calibration or adjustment.
- Internal reference cell in the Laser Detector Module ensures peak locking during trace measurements.
- Laser Detector Modules are isolated from aggressive and corrosive processes.
- On board diagnostics and low TCO(*1) (no moving parts, high MTTF(*2) for components)
*1: Total Cost of Ownership
*2: Mean Time To Failure
• IEC61508 SIL certified,
SIL 2 capability for one TDLS8200 use,
SIL 3 capability for duplicate TDLS8200s use
• Intuitive touchscreen HMI YH8000
- YH8000 offers intuitive touch screen operation and simple menu structure in multiple languages allowing for control of up to four analyzers simultaneously (including TDLS8000)
• HART and Modbus TCP communications standard
• 8-stage auto-gain adapts to difficult applications
- Auto-gain enables wide signal ranges against dynamic variation of transmission.
• Full field serviceability with 50 days of data and spectra storage
• FM (US, Canada), IECEx, ATEX/UKEX hazardous
area, Korea, NEPSI, Japan approvals based on Explosionproof/flame proof.
• In-situ analysis and near real time measurements
(2-5 seconds, 1 second optional)
• Process pressures up to 500 kPa abs., process temperatures up to 850ºC, and process gas flow velocity 1 m/s or more.
Note: Maximum process temperatures, pressures, and flow velocity will vary by application.
Typical gases measured include:
• Oxygen, carbon monoxide, and methane in process applications.
Process temperatures can be as high as 850ºC, and process pressures can be as high as 500kPa abs.