PRODUCTS
CONTACT US
Address: Building 2, North area of LvDiQihang Plaza,houshayu, Shunyi District, Beijing
Landline: 86-010-69450179
Mobile: 86-18600796106
Engine cooling water flow meter EF-AUTO
This product miniaturizes the electrical wiring part of the detector of the electromagnetic flowmeter suitable for engine cooling water flow measurement, making it easy to install in the engine compartment of the test vehicle and convenient to connect with the engine cooling water hose.
Classification:
Tokyo Keiso
Keywords:
Hotline:
Product description
Overview
This product miniaturizes the electrical wiring part of the detector of the electromagnetic flowmeter suitable for engine cooling water flow measurement, making it easy to install in the engine compartment of the test vehicle and convenient to connect with the engine cooling water hose.
Features
• The inlet and outlet joints of the flowmeter can be disassembled and replaced, and the joints can be processed according to the inner diameter of the engine cooling water hose. In addition, for different sizes of engine cooling water hose, only need to replace the inlet and outlet joints can be measured.
• There is no protrusion in the flow path, and the pressure loss is small. The influence of upper and lower flow piping is small, and the requirement for straight pipe length is low.
• The electrical connection part of the detector has been miniaturized, and the signal line has a special connector to realize quick connection.
Measuring principle
The nonmagnetic measuring tube has a pair of electrodes in contact with the liquid, and excitation coils are arranged in the upper and lower portions of the flow path in the direction perpendicular to the axis of the electrodes.
A magnetic field can be generated by adding an excitation current to the excitation coil. When the cooling water flow, according to the principle of Faraday electromagnetic induction, a voltage proportional to the flow rate is generated between the electrodes. The flow rate can be obtained by measuring the voltage, and the flow rate can be calculated according to the cross-sectional area of the pipeline.
Specifications
Detector/Converter: EGS5000 detector/EGC300W or EGC100W converter
Production caliber: 6, 10, 15, 25, 40, 50mm
Fluid temperature:-20~180 ℃
Fluid pressure: 0.0 ~ 1.0MPa
Accuracy: 0.5% Reading
Connection: hose joint
electrical connection: electrode signal cable
(Excitation current cable
Standard length of signal line 10m)
Construction: waterproof type (IP65 equivalent)
Material
Shell: diameter 6~15mm; stainless steel casting (SCS13 equivalent)
Caliber 25~50mm; stainless steel (SCS304 equivalent)
Hose joint: SUS304 and aluminum alloy * 1
Wiring connection: aluminum alloy * 1
Sealing gasket: fluorine rubber * 1 aluminum alloy surface spraying.
Analog signal output: DC4-20mA output, load resistance below 1KΩ
Power supply: AC100 ~ 230V(AC85 ~ 250V free power supply)
or DC 24V(9~31V)
Power consumption: about 22VA
Detector installation: motor shaft horizontal position installation.
Converter installation method: wall installation
※ other specifications are the same as EGS5000 detectors and EGC300W or EGC100W converters.