  • zk67.jpg

High temperature gas flow meter VC-1200/EDR-N7C

The flowmeter adopts the V-cone measurement principle, which can be used for stable measurement of high-temperature gas, save space, low pressure loss, and can resist oil and other impurities. It is the choice for high-temperature gas flow measurement.

Classification:

Tokyo Keiso

Keywords:


Hotline:

Product description

Summary

This flowmeter is used to measure high temperature gas flow meter.

The flowmeter adopts the V-cone measurement principle, which can be used for stable measurement of high-temperature gas, save space, low pressure loss, and can resist oil and other impurities. It is the choice for high-temperature gas flow measurement.

V-cone flowmeter is a differential pressure flowmeter with many special features such as short straight tube length, stable flow (differential pressure) signal, no accumulated liquid or impurity part, etc. It is made of stainless steel, so it can correspond to the flow measurement of high temperature gas below 800 ℃, which is the best choice for flow measurement of engine exhaust system.

V-cone flowmeter and differential pressure transmitter (EDR-N7C) with temperature and pressure compensation function can be used in combination to automatically compensate for temperature and pressure, and can also perform high-precision mass flow measurement under the condition of fluid temperature and pressure changes.

Features

●Compact structure, short length of straight tube, saving space

● Can correspond to high temperature fluid

● Good stability of differential pressure signal

● Low pressure loss

● No accumulation of liquid or other impurities

● Mass flow measurement

● Range ratio width

Standard Specifications

● Sensor VC-1200

Caliber: DN15-DN1500

Connection: can be customized according to customer requirements

Measurement object: gas, steam

Accuracy: ± 2% F.S. (combined accuracy with differential pressure transmitter)

Fluid temperature:-20~800 ℃

Fluid pressure: 0.05 ~ 5MPa(abs)

Material: SUS304

● Differential pressure transmitter EDR-N7C

Measuring differential pressure range: 0.8 ~ 80kPa

Response speed: about 1.3sec

Output: DC4-20mA

Power supply: DC11.4 ~ 50.4V

Terminal: G1/2

Material: SUS316

Protection class: IP67

Accessory function: temperature and pressure compensation

Measuring principle

The measurement principle of V-cone flowmeter is the same as that of general differential pressure flowmeter, which is based on Bernoulli fluid energy conservation theorem.

As shown in the figure below, when the fluid approaches the V cone, the pressure of the fluid is P1. Then as the fluid passes through the V-cone, the flow rate of the fluid increases and the pressure of the fluid decreases to P2.

P1 and P2 are taken out from different pressure ports, and the differential pressure (ΔP) is calculated as the flow rate of the fluid through the differential pressure transmitter.

 